A solenoid valve is an electromechanical valve frequently used to control the flow of liquid or gas. Solenoid valves are found in many applications and are commonly used in refrigeration and air conditioning systems. Their function is simply to turn refrigerant flow on and off.

How does a solenoid valve work?

Solenoid valves consist of a coil, plunger and sleeve assembly. In normally closed valves, a plunger return spring holds the plunger against the orifice and prevents flow. Once the solenoid coil is energized, the resultant magnetic field raises the plunger, enabling flow.

What is the use of solenoid valve in chiller?

A solenoid valve opens which allows the discharge hot gas to bypass the expansion valve and return to the suction. It can open and close as many times as needed to achieve a very close control, while at the same time allowing the compressor to run normally.

How does a compressor solenoid valve work?

A solenoid valve intercepts compressed air from the system and shoots it against the small parts to push them into the assembly machine. A photocell is at the mouth of the feeder.

What is the purpose of the liquid solenoid?

The Liquid-Line Solenoid Valve holds refrigerant in the liquid line when the system is not running. The liquid-line solenoid valve closes when the thermostat demand is satisfied to prevent liquid refrigerant migration. This device is for use in long-line applications.

What is the use of solenoid?

The main use of solenoid is as a switch for power. They are used in inductors, valves, antennas, etc. Its application is in varied fields like medical, industrial use, locking systems, automotive, etc. It is used to control a valve electrically.

Why do we need solenoid valve?

Solenoid valves are used wherever fluid flow has to be controlled automatically. They are being used to an increasing degree in the most varied types of plants and equipment. The variety of different designs which are available enables a valve to be selected to specifically suit the application in question.

How do solenoids fail?

Solenoid coil failure can be caused by a number of factors. Applying an incorrect voltage to the coil will cause it to fail and may cause the coil to burn out. Electrical surges or spikes may also damage the coil. Burnt out coils cannot be repaired and will need to be replaced.

Where are solenoid valves used?

Common uses. Solenoid valves are used in fluid power pneumatic and hydraulic systems, to control cylinders, fluid power motors or larger industrial valves. Automatic irrigation sprinkler systems also use solenoid valves with an automatic controller.